Multifunction Indoor DC Voltage and Current Sensors

HaslerRail has been serving the rail industry since 1887. With thousands of installations in service worldwide, we have built up broad, deep knowledge of energy metering and management for rolling stock. Our multifunction indoor DC voltage and current sensors are based on this experience.

Multifunction Indoor DC Voltage and Current Sensors

HaslerRail has been serving the rail industry since 1887. With thousands of installations in service worldwide, we have built up broad, deep knowledge of energy metering and management for rolling stock. Our multifunction indoor DC voltage and current sensors are based on this experience.

Features / Benefits

  • Energy measurement and traction control
  • Suitable for distributed traction architectures
  • Current loop or serial interface for noise immunity
  • Optional analog and serial interfaces
  • External shunt to adapt current to consumption
  • Insulated input terminals for limited space
  • Safe against internal arcs
  • Expert customer support
  • Worldwide after-sales service

iTEMS-ECF is Sécheron Hasler Group’s integrated DC voltage and current sensor for rail vehicles. It is used indoors for voltage detection, traction control, and energy measurement on systems ranging from 600 VDC to 3,000 VDC. It is designed specifically for distributed traction architectures and is available in a variety of configurations to implement different combinations of the Voltage Measurement Function (VMF) and Current Measurement Function (CMF). If both the current and voltage interfaces are present, iTEMS can deliver the Energy Calculation Function (ECF). The measured and calculated values are securely and accurately transmitted to various on-board equipment via a traditional analog interface or a serial communication bus.

iTEMS-ECF can be delivered as a stand-alone device for installation by car builders and operators. It can also be integrated into Sécheron Hasler Group’s MODBOX® enclosures, or with Sécheron Hasler Group’s comprehensive Energy Management System, which also includes the REM102 Energy Meter with DHS and DCS.

All of our products are backed by HaslerRail experts, who provide recommendations and support throughout the project lifecycle, and Sécheron Hasler Group’s worldwide network of service locations for assistance throughout the product lifetime.

Product Description

  • DC applications: 600V, 750V, 1.5KV and 3KV
  • Maximum permanent measured voltage 4500 V
  • Maximum peak measured voltage 4500 V
  • Impulse withstand voltage 40 kV
  • Overvoltage category OV4
  • Optional 2+2 isolated analog outputs, current loop type
  • Bipolar type outputs
  • Bipolar output: maximum output current = 20mA
  • Measuring resistance: 10 to 200 Ohms
  • VMF, CMF Accuracy class 0.5R
  • ECF Accuracy class 0.2R
  • Auxiliary supply voltage models: 24 VDC , 36-48 VDC, 72-110VDC
  • Vertical & horizontal installation
  • Indoor installation
  • Protection index IP51
  • Dimensions: 170mm(H) x 200mm(D) x 130 (W)
  • Weight: 3.5 kg
  • Suitable for ambient temperature – 40°C to +70°C
  • Reference standards: EN 50463-2 / IEC 62888-2
  • Insulation material according to EN 45545-2